Failure to align a pump with a basic coupling during mounting can lead to premature wear on the coupling, pump, and motor bearings, as well as increased vibration and noise. Misalignment can also cause uneven loading on the motor and pump, leading to reduced efficiency, increased energy consumption, and potentially even motor or pump failure. In extreme cases, misalignment can cause the coupling to fail, resulting in costly repairs and downtime.