الهندسة والمعرفة

الأساسيات والهندسة

حسابات تحميل Hvac

The accurate calculation of heating and cooling loads is essential to provide a sound bridge between fundamental building design decisions and an operating building. If loads are substantially underestimated, occupants and users will likely be hot or cold. If loads are substantially overestimated, equipment will be oversize (usually wasting money, reducing efficiency, increasing energy consumption, and often imperiling comfort).

زوايا الطاقة الشمسية - أساسيات تحديد المواقع الشمسية

Two fundamental parameters determine how effectively your solar panels capture sunlight: orientation and tilt. These factors, when properly calculated, can significantly increase your system’s efficiency and return on investment.

فهم الإشعاع الشمسي: مصدر الطاقة القوي للأرض

Solar energy is the result of electromagnetic radiation released from the sun by the thermonuclear reactions occurring inside its core. All of the energy resources on earth originate from the sun (directly or indirectly), except for nuclear, tidal, and geothermal energy.

سابق

المعايير والامتثال

تصميم قناة HVAC: خسارة الاحتكاك في تجهيزات القناة

Complete guide to HVAC duct fittings friction loss using Carrier standards covering loss coefficients, pressure drop calculations, and system optimization for efficient air distribution design.

تصميم قناة HVAC: مخمدات ، مخففات ، وفقدان الاحتكاك لفائف

Complete guide to HVAC dampers, attenuators, and coils friction loss using SMACNA standards covering pressure drop calculations, component selection, and system optimization for efficient air distribution design.

تصميم قناة HVAC: قناة جولة إلى ما يعادلها مستطيلة

Complete guide to HVAC round-to-rectangular duct equivalency using ASHRAE standards covering conversion formulas, performance considerations, and system optimization for space-constrained installations.

تصميم قناة HVAC: فقدان احتكاك القناة

Complete guide to HVAC duct friction loss calculations using ASHRAE standards covering friction charts, pressure drop analysis, and system optimization for efficient air distribution design.

تصميم قناة HVAC: تصنيف ضغط القناة

Complete guide to HVAC duct pressure classification using SMACNA standards covering pressure class selection, construction requirements, and testing protocols for safe and efficient ductwork systems.

تصميم قناة HVAC-قناة التحجيم الملوثية (الدخان | الشحوم | الغازات | الغبار الجاف والرطوب)

ASHRAE’s Pocket Guide lists minimum conveying velocities that keep contaminants airborne while they travel through exhaust ductwork. Table 2.9 (2013 edition, Ch. 02, pp. 60

تصميم قناة HVAC: تغيير حجم قناة المطبخ التجاري

Complete guide to commercial kitchen duct sizing using ASHRAE and NFPA standards covering exhaust hood design, grease management, fire safety, and make-up air systems for food service operations.

تصميم قناة HVAC: تحجيم القناة حسب معايير السرعة والضوضاء (NC)

Complete guide to HVAC duct sizing using velocity and noise criteria with ASHRAE and CIBSE standards covering acoustic design, velocity limits, and noise control for sensitive applications.

تصميم قناة HVAC: تحجيم القناة بواسطة طريقة الاحتكاك المتساوي

Complete guide to HVAC duct sizing using the equal friction method with SMACNA and ASHRAE standards covering calculation procedures, friction rate selection, and system optimization for effective air distribution design.

تصميم قنوات التدفئة والتهوية وتكييف الهواء: توصيات SMACNA لتحجيم مجاري الهواء

Complete guide to HVAC duct sizing using SMACNA recommendations covering equal friction, velocity, and static regain methods with design calculations and system optimization for effective air distribution.


الأدوات والموارد الرقمية

تصنيف كفاءة مرشحات الهواء

ASHRAE 52.2: Filter testing was originated from America in 1930 (ASHVE and AFI code). It was then reviewed and modified in 1967 and 1968. ASRHAE collaborated with American National Standard Institude (ANSI) in 1992 to create ASHRAE-ANSI 52.1. Finally updated to ASHRAE 52.2 in 2007.

وظائف البرمجة السيكرومترية

ibrary of psychrometric functions to calculate thermodynamic properties of air for Python, C, C#, Fortran, JavaScript and VBA/Excel

المبردات في عام 2025: الخصائص والتطبيقات والتوافق

As the HVAC and refrigeration industry continues to evolve with environmental regulations and technological advancements, understanding refrigerant properties remains crucial for engineers, technicians, and facility managers. This comprehensive guide provides an updated overview of common refrigerants, their compositions, and applications in today’s market.

برامج هاب الناقل

Carrier’s Hourly Analysis Program is two powerful tools in one package – versatile features for designing HVAC systems for commercial buildings AND powerful energy analysis capabilities for comparing energy consumption and operating costs of design alternatives.

برنامج Trace 700

TRACE 700 enables building designers to optimize the building, system and equipment designs on the basis of energy utilization and life-cycle cost. The Trane software for TRACE 700 facilitates analysis of the energy and economic effects of virtually any chiller plant configuration by allowing users to manipulate a wide range of variables and create a profile of their specific building.

تنزيل EVAP-COND 5.0: أداة محاكاة المبادل الحراري النهائية لمهندسي التدفئة والتهوية وتكييف الهواء (HVAC).

سواء كنت تصمم مبادلًا حراريًا جديدًا، أو تعمل على تحسين نظام موجود، أو تبحث عن مبردات بديلة، فإن EVAP-COND يوفر إمكانات التحليل التفصيلي اللازمة لاتخاذ قرارات مستنيرة. أنا أشجع جميع مهندسي وباحثي التدفئة والتهوية وتكييف الهواء (HVAC) على استكشاف أداة المحاكاة القوية هذه وتجربة كيفية تحويل أسلوبك في تصميم المبادلات الحرارية بشكل مباشر.

تنزيل كتاب نقل الحرارة

The book is meant for juniors, seniors, and first-year graduate students. And to those who choose to learn the subject on their own, and to practicing engineers who use it as a reference. Whether one studies alone or with a class, learning means posing, then answering, one’s own questions.

Flexible Duct Calculator

Flexible Duct Calculator based on four different methods. Based on Friction Loss, Based on Duct Diameter, Equivalent Rectangular Duct, Equivalent Round Duct Diameter. Also table of Maximum Recommended Supply Velocity.

تغيير الهواء Cfm حاسبة

The rate at which air is exchanged (in the premises) represents another method of measuring ventilation capacity & effectiveness. Air exchange rate is typically expressed in Air Changes per Hour – “ACH”. Air changes per hour can be estimated by determining the total air supplied to, and removed from, the premises “total air exchange” or the outdoor (fresh) air supplied to, and removed from, the premises “outdoor air exchange”. We invite you to experience how this calculator can transform your workflow. Whether you’re specifying a new system, troubleshooting an existing installation, or teaching the next generation of HVAC professionals, this tool was built with your needs in mind.