Equipaggiamento e sistemi
Preheat Coil Piping Diagrams
Preheat coils are essential components of HVAC systems, helping to protect other equipment from freezing and improve efficiency. Preheat coil piping diagrams are essential tools for HVAC professionals to design, install, and troubleshoot preheat coils.
Air-Cooled vs. Water-Cooled Chillers: Selection Criteria
Compare air-cooled vs. water-cooled chillers. Understand selection criteria to make the best choice for your cooling needs.
Processo di dimensionamento e selezione delle valvole di espansione per refrigerazione
The proper selection and sizing of refrigeration expansion valves is a systematic process requiring careful consideration of multiple parameters. Selecting the right expansion valve involves understanding system requirements, calculating correct capacities, and accounting for operating conditions such as subcooling and pressure drop.
Refrigeration Condenser Sizing and Selection
The proper sizing and selection of refrigeration condensers is a complex process that requires careful consideration of multiple factors, including heat load calculations, environmental conditions, system requirements, and efficiency goals. By following a structured approach that considers all relevant parameters, engineers can select condensers that provide optimal performance while minimizing energy consumption and maintenance requirements.
Constant Volume Air Handling
Constant Volume Air Handling design principles and control strategies, with particular emphasis on energy optimization and frost protection mechanisms.
Regole empiriche del carico di raffreddamento
Cooling Load Rules Of Thumb for HVAC design of Banks, Court Houses, Municipal Buildings, Town Halls, Police Stations, Fire Stations, Post Offices, Precision Manufacturing, Computer Rooms, Restaurants, Kitchens (Depends Primarily on Kitchen Equipment), Cocktail Lounges, Bars, Taverns, Clubhouses, Nightclubs, Hospital Patient Rooms, Nursing Home Patient Rooms Buildings w/100 percent OA Systems (e.g., Laboratories, Hospitals) Medical/Dental Centers, Clinics, and Offices Residential Apartments (Eff., One-Room, Two-Room) Motel and Hotel Public Spaces Motel and Hotel Guest Rooms, Dormitories School Classrooms Dining Halls, Lunch Rooms, Cafeterias, Luncheonettes Libraries, Museums Retail, Department Stores Drug, Shoe, Dress, Jewelry, Beauty, Barber, and Other Shops Supermarkets Malls, Shopping Centers Jails Auditoriums, Theaters Churches Bowling Alleys
Induction (Air/Water) System
Perimeter induction units – usually located under windows – blend primary air from the air-processing unit with secondary air from within the room. The high-velocity processed air delivery is induced into the unit through restrictive nozzles.
Condizioni di progettazione per interni
Indoor design conditions for HVAC design of Office Buildings, Commercial Facilities General Spaces, Educational Facilities, Food and Beverage Service, Hotels, Motels, Resorts, and Dormitories, Correctional Facilities, Retail Stores and Specialty Shops Theaters, Sports and Entertainment, Transportation, Storage Facilities, Workrooms, Private Dwelling—Single and Multiple, Laboratories, Computer Facilities, High-Tech Industrial, Special Facilities, Hospital Nursing Units Obstetrical Facilities, Emergency, Surgery, and Critical Care, Hospital Facility Support Areas, Diagnostic and Treatment Areas, Hospital Service Areas Sterilizing and Supply…
Fancoil (Air/Water) Unit And Induction Diffuser
An alternative discharge unit for application to the induction system shown on the previous page. Instead of nozzle injection of air, a low-powered fan is used to disperse a mixture of primary and secondary air after reheating or cooling from an energy exchanger within the unit.
Dual Duct System
The dual duct system is another means of providing varying air temperatures to different rooms in the same building. There is no water circulation to peripheral discharge units with terminal reheaters or coolers. This simplifies the plumbing installation as heating and cooling elements for each duct are located in the plant room. However, the system is space consuming and adequate provision must be made in suspended ceilings or raised flooring to accommodate both distribution ducts. The system is most energy economic when heating and cooling elements operate individually.
Controlli e automazione
Raffreddamento a liquido diretto su chip: il futuro della gestione termica dei data center ad alta densità
Data center power densities have surged to 12-30 kW per rack, making liquid cooling essential. Learn how single-phase and two-phase direct-to-chip systems work, refrigerant selection criteria, and critical design considerations for hoses, tubing, and couplings in modern high-density data centers.
Diagrammi di controllo HVAC
In questo post del blog introdurremo alcuni dei diagrammi di controllo HVAC più comuni. Forniremo inoltre una breve spiegazione di ciascun diagramma e di come i suoi componenti interagiscono. Gli schemi di controllo HVAC sono strumenti essenziali per la progettazione, l'installazione e la manutenzione dei sistemi HVAC. Forniscono una rappresentazione visiva dei componenti del sistema, di come sono interconnessi e di come sono controllati. Queste informazioni possono essere utilizzate per risolvere problemi, ottimizzare le prestazioni e prendere decisioni informate sugli aggiornamenti del sistema.