概要
Chvac quickly and accurately calculates the maximum heating and cooling loads for commercial buildings. The cooling loads can be calculated with either the CLTD method or the new RTS (Radiant Time Series) method. The program allows an unlimited number of rooms which can be grouped into as many as 100 air handling systems. Chvac automatically looks up all cooling load and correction factors necessary for computing loads. In addition, it can look up outdoor design weather data for over 2000 cities located around the world. There is also provision for editing the weather data as well as adding data for other cities. Comprehensive reports list the general project data, detailed room loads, air handler summary loads, outside air loads, total building loads, building envelope analysis, tonnage requirements, CFM air quantities, chilled water flow rates (if applicable), and complete psychrometric data with entering and leaving coil conditions. Other outstanding features include ASHRAE Standard 62 analysis, automatic building rotation, 360 degree wall orientations, tilted glass, exterior shading, internal operating load profiles, variable indoor design temperatures, people diversity, pretreated outside air, seasonal infiltration and ventilation rates, reheat loads, duct gains and losses, and return air plenums.
計算方法
Chvac performs cooling calculations using either the CLTD method or the new RTS (Radiant Time Series) method. The RTS method is described in the latest edition of the ASHRAE Handbook of Fundamentals, while the CLTD method is from earlier editions of the Handbook. The RTS method is especially accurate because it calculates the delayed effect of radiant heat gains during each of the past 24 hours in determining the current cooling load. That means, for example, that the program gives proper consideration to the effect of an external shading device that shades a window in the morning in a room that peaks in the afternoon. The CLTD method, on the other hand, uses exact table values from the Handbook where possible, which means that you can verify the results by hand. You can actually switch back and forth between RTS and CLTD for any project. All you have to do to switch between the two methods is to enter equivalent Master Data definitions for roofs, walls and glass and then change the Cooling Calculation Method input to the other method.
特長
- ピーク冷暖房負荷を計算
- 加熱と冷却の両方の CFM 要件を計算
- 振れと主幹ダクトのサイズを計算します
- ASHRAE 標準 62 への準拠を自動化
- 建物全体のエンベロープレポートを提供します
- 計算結果を含むスプレッドシート ファイルを作成します
- 完全な乾湿分析を実行
- 棒グラフと展開円グラフを印刷します
- エクステリア シェーディング ハンドル オーバーハング、フィン、ガラスの傾斜
- 正確な ASHRAE RTS または CLTD 手順を使用
- 数百の都市の組み込み設計気象データ
- 計算ごとに最大 12 か月を分析
- 設計日あたり 24 時間を計算します
- プロジェクトごとに無制限の部屋数を許可
- 部屋は 100 人の空調担当者の下にグループ化される場合があります
- ルームはオプションで VAV ボックスの下にグループ化できます
- 部屋ごとに 100 個の壁、100 個の窓、100 個の屋根を許可
- 浸透と換気を同時に可能
- 夏期と冬期の異なる航空料金を許可
- 部屋ごとに異なる室内条件を許容
- 20 個のマスター屋根タイプ、20 個のマスター壁タイプ、20 個のマスター パーティション タイプ、および 50 個のマスターガラス タイプを使用可能
- カスタムマテリアルのユーザー定義ライブラリを提供します
- お気に入りのマテリアルのリストを提供します
- 最大 10 個の内部動作負荷プロファイルが可能
- 壁とガラスの向きを 360 度完全に調整可能
- Glass を 0 度から 180 度まで傾けることができます
- 屋根と壁の色の効果を可能にします
- VAV と定容量システムの両方のプロビジョニング
- 戻り空気プレナム負荷の適切な取り扱い
- 建物の総荷重における人々の多様性の考慮
- 供給ファンの馬力と熱利得を計算します
- ドロースルーファンとブロースルーファンの両方を考慮
- 必要に応じて再加熱要件を計算します
- 供給ダクトと戻りダクトの利得と損失を計算します
- 供給CFM数量の直接指定が可能
- 最小供給空気量の指定が可能
- 加熱のみ、冷却のみ、または両方を許可
- 過剰な供給空気は、再加熱、予備容量として、または放置コイル条件を調整することで処理できます。
- 希望の乾球温度または相対湿度で放置コイル条件を指定可能
- 冷水および温水コイルの流量を計算します
- 前処理された外気の導入が可能
- Calculates benefits of Heat Recovery Ventilators (HRV) for heating and cooling
- 加熱および冷却の安全率を考慮
- 照明と機器のワット数と人数を直接入力することも、平方フィートごとに入力することもできます
- ARI/GAMA データベースから機器を選択します
- カスタム販売提案を作成します
- スプレッドシート出力ファイルを作成します