Engenharia e Conhecimento

Fundamentos e engenharia

Hvac Air Volume Calculation

The air volume for an HVAC system is calculated from the sensible heat in the conditioned space. For the typical heating and cooling unit, the calculation is for cooling because more air is needed to cool a space than to heat it. If the conditioned space can be properly cooled with a given amount of cfm, then the space can be heated correctly with the same amount of cfm.

Thermal Storage (HVAC)

Thermal energy may be stored in three main ways: – Sensible Storage – Latent Storage – Thermo-Chemical Storage. In addition, the two common thermal storage strategies employed are: – Load Levelling Strategy – Load Shifting Strategy

Dimensionamento de Tanques Hidropneumáticos

Hydropneumatic tanks are primarily used in a domestic water system for draw down purposes when the pressure booster system is off on no-flow shutdown (NFSD). The NFSD circuitry turns the lead pump off when there is no demand on the system. While the system is off in this condition, the hydropneumatic tank will satisfy small demands on the system. Without the tank, the booster would restart upon the slightest call for flow such as a single toilet being flushed or even a minute leak in the piping system. Hydropneumatic tank sizing is dependent on two factors: – Length of time you wish the pumps to remain off in a no-flow situation. – The tank location in relation to the pressure booster.

Pump Sizing Core Concepts

Pump sizing involves matching the flow and pressure rating of a pump with the flowrate and pressure required for the process. The mass flowrate of the system is established on the process flow diagram by the mass balance. Achieving this mass flowrate requires a pump that can generate a pressure high enough to overcome the hydraulic resistance of the system of pipes, valves, and so on that the liquid must travel through. This hydraulic resistance is known as the system head.

Hvac Equations (U.S./Metric)

The heating, ventilation, and air conditioning (HVAC) equations. In both U.S. and Metric units.

Expansion Tanks

How does Boyle’s law relate to sizing expansion tanks in domestic hot water systems? what size expansion tank is required?

Expansion Tank Sizing Formulas

Expansion tanks are a necessary part of all closed hydronic systems to control both minimum and maximum pressure throughout the system. A comprehensive review of tank types and sizing procedure for expansion tanks.

Primary Secondary Pumping

– What is Primary-Secondary Pumping? – PRIMARY-SECONDARY BASICS. – PRIMARY-SECONDARY RULES, DEFINITIONS. WHEN TWO PIPING CIRCUITS ARE INTER-CONNECTED, FLOW IN ONE WILL CAUSE FLOW IN THE OTHER, T0 A DEGREE DEPENDING UPON THE PRESSURE DROP IN THE PIPING COMMON T0 BOTH.

Plantas de aquecimento e resfriamento de 4 e 2 tubos

A 4-pipe heating and cooling plant contains both central heating and cooling equipment and is capable of delivering heating water and chilled water to the building simultaneously through four pipes (one heating water supply, one heating water return, one chilled water supply, and one chilled water return). Heating and cooling equipment within the building that is connected to a 4-pipe system will have four pipe connections, unless the equipment provides either heating only or cooling only. In this case, the equipment would have only two pipe connections.

Constant Air Volume (CAV) Systems

HVAC air systems can be either centralized or decentralized. Centralized air systems receive their cooling and heating energy from a remote central plant. Decentralized HVAC air systems contain the central heating and cooling plant equipment within the air system itself. HVAC air systems can also be constant air volume (CAV) or variable air volume (VAV). CAV systems deliver constant supply airflow at a variable temperature. VAV systems deliver variable supply airflow at a constant temperature. CAV and VAV air systems can be further subdivided into systems that condition a single temperature zone and systems that condition multiple temperature zones.

Anterior

Padrões e conformidade

HVAC Duct Design: Duct Fittings Friction Loss

Complete guide to HVAC duct fittings friction loss using Carrier standards covering loss coefficients, pressure drop calculations, and system optimization for efficient air distribution design.

Projeto de duto HVAC: amortecedores, atenuadores e perda por fricção de bobinas

Complete guide to HVAC dampers, attenuators, and coils friction loss using SMACNA standards covering pressure drop calculations, component selection, and system optimization for efficient air distribution design.

Projeto de duto HVAC: Duto redondo a equivalente retangular

Complete guide to HVAC round-to-rectangular duct equivalency using ASHRAE standards covering conversion formulas, performance considerations, and system optimization for space-constrained installations.

Projeto de duto HVAC: Perda por fricção do duto

Complete guide to HVAC duct friction loss calculations using ASHRAE standards covering friction charts, pressure drop analysis, and system optimization for efficient air distribution design.

Projeto de duto HVAC: classificação de pressão do duto

Complete guide to HVAC duct pressure classification using SMACNA standards covering pressure class selection, construction requirements, and testing protocols for safe and efficient ductwork systems.

Projeto de duto HVAC – Dimensionamento de dutos de extração de contaminantes (fumaça | graxa | gases | poeira seca e úmida)

ASHRAE’s Pocket Guide lists minimum conveying velocities that keep contaminants airborne while they travel through exhaust ductwork. Table 2.9 (2013 edition, Ch. 02, pp. 60

Projeto de duto HVAC: dimensionamento de dutos de cozinha comercial

Complete guide to commercial kitchen duct sizing using ASHRAE and NFPA standards covering exhaust hood design, grease management, fire safety, and make-up air systems for food service operations.

HVAC Duct Design: Duct Sizing by Velocity & Noise Criteria (NC)

Complete guide to HVAC duct sizing using velocity and noise criteria with ASHRAE and CIBSE standards covering acoustic design, velocity limits, and noise control for sensitive applications.

Projeto de duto HVAC: Dimensionamento de duto pelo método de fricção igual

Complete guide to HVAC duct sizing using the equal friction method with SMACNA and ASHRAE standards covering calculation procedures, friction rate selection, and system optimization for effective air distribution design.

HVAC Duct Design: Duct Sizing SMACNA Recommendations

Complete guide to HVAC duct sizing using SMACNA recommendations covering equal friction, velocity, and static regain methods with design calculations and system optimization for effective air distribution.


Ferramentas e recursos digitais

Belimo SelectPro – Download grátis

Download SelectPro desktop app free. Size and select valves, actuators, and sensors with export builder, quote generator, and centralized reference documents. For HVAC engineers and contractors.

Taxas de expansão térmica para materiais de tubos comuns

Effortlessly calculate rates of thermal expansion for common pipe materials with our interactive calculator. Get accurate data, design insights, and actionable tables for metals and plastics—essential for HVAC engineers, designers, and consultants focused on system reliability and energy efficiency.

Calculadora de expectativa de vida de equipamentos HVAC

We’ve created a professional HVAC equipment life expectancy calculator. The application provides comprehensive calculations for determining the remaining useful life of various HVAC equipment types.

Soluções de software BIM para aplicações modernas de HVAC

As the HVAC industry continues to evolve in 2025, Building Information Modeling (BIM) has become an indispensable tool for professionals seeking to optimize design, installation, and maintenance processes. For HVAC engineers, contractors, and technicians, selecting the right BIM software can significantly impact project efficiency and outcomes. Let’s explore the most effective BIM solutions for HVAC applications.

McQuay Softwares Download

McQuay (As part of Daikin Industries) is one of the largest air conditioning, heating, ventilating and refrigeration companies in the HVAC/R industry. Therefore, we decided to make some softwares that this company has introduced to the industry based on their experience and knowledge available for download.

Oportunidades de Carreira Hvac

The HVAC/R (heating, ventilating, and air conditioning / refrigeration) industry is rapidly changing due to advancements in technology being spurred on by the need for increased energy efficiencies. Accordingly, the career opportunities open to an individual seeking employment in HVAC fields can be divided roughly into four categories, each dependent upon a different type or degree of education and/or training.

Softwares de seleção Bell & Gossett

#Xylem Bell & Gosset #Selection, #Sizing & #CAD Tools and #Softwares

Tabelas de Cronogramas de Tubulação

Pipe Schedule (SCH) is a standard that measures the nominal wall thickness of a pipe. The pipe schedule number is non-dimensional and depends on the nominal pipe size, internal pipe working pressure, and the material used for the pipe wall.

Piping Tools (Excel Files)

More than 165 spreadsheets (excel xls files) for a comprehensive range of calculation in Fluid, Thermal and piping engineering.

Daikin Revit Files

DAIKIN APPLIED RESOURCE LIBRARY – REVIT FILES Rooftop Systems Air Handlers – Outdoor Air Cooled Chillers Water Cooled Chillers Fan Coils Self-Contained Water Source Heat Pump Unit Ventilators