Fondamentaux Et Ingénierie
Procédures de conception pour les systèmes de chauffage uniquement : une méthodologie en 8 étapes
Designing effective heating-only HVAC systems requires a methodical approach that ensures adequate capacity while avoiding oversizing. The following 8-step procedure provides a comprehensive framework for designing these systems, focusing on peak heating loads to determine appropriate equipment sizing.
Calculs de dimensionnement du débit d'air d'espace et de zone dans les systèmes CVC
Following our previous discussion on the systematic 9-step procedure for designing cooling and heating systems, it’s essential to understand the technical aspects of airflow sizing
Design Procedures for Cooling-Only Systems: Detailed Airflow Calculation Methodology
this technical supplement provides detailed insights into the critical airflow calculation methods essential for Step 3: Calculate Required Zone and Space Supply Airflow Rates. Understanding these calculation approaches enables engineers to select the most appropriate sizing method for specific project requirements.
Procédures de conception pour les systèmes de chauffage uniquement: méthodes de calcul du flux d'air et considérations techniques
Proper airflow calculations are essential for system performance, ensuring thermal comfort while optimizing energy efficiency. Understanding the mathematical foundation behind these calculations enables engineers to make informed decisions when selecting the most appropriate sizing method for specific project requirements.
Processus de dimensionnement et de sélection des soupapes d'extension de réfrigération
The proper selection and sizing of refrigeration expansion valves is a systematic process requiring careful consideration of multiple parameters. Selecting the right expansion valve involves understanding system requirements, calculating correct capacities, and accounting for operating conditions such as subcooling and pressure drop.
Dimensionnement et sélection de l'évaporateur de réfrigération
Le dimensionnement et la sélection des évaporateurs représentent des éléments critiques dans la conception du système de réfrigération. Le processus nécessite une approche méthodique qui considère non seulement la charge de refroidissement mais également l'intégration du système, les propriétés de réfrigérant, les exigences d'application et les objectifs d'efficacité énergétique.
Lighting Rules Of Thumb (HVAC)
Using lighting rules of thumb for final design of HVAC and lighting.
Infiltration Rules Of Thumb
The infiltration rate is the volumetric flow rate of outside air into a building, typically in cubic feet per minute (CFM) or liters per second (LPS). The air exchange rate, (I), is the number of interior volume air changes that occur per hour, and has units of 1/h.
La géométrie derrière les calculs d'énergie solaire
Solar Geometric Angles are all critical to the calculation of solar energy on any given surface at some orientation. To calculate the energy balance across any time scale with respect to the incident solar radiation, you must know the geometric relationships that define the spherical realities of planetary motion relative to the sun for specific tilted surfaces on the planet.
Normes Et Conformité
Conception du conduit HVAC: Perte de friction des raccords de conduit
Complete guide to HVAC duct fittings friction loss using Carrier standards covering loss coefficients, pressure drop calculations, and system optimization for efficient air distribution design.
Conception du conduit HVAC: amortisseurs, atténuateurs et pertes de frottement des bobines
Complete guide to HVAC dampers, attenuators, and coils friction loss using SMACNA standards covering pressure drop calculations, component selection, and system optimization for efficient air distribution design.
Conception du conduit HVAC: conduit à l'équivalent rectangulaire
Complete guide to HVAC round-to-rectangular duct equivalency using ASHRAE standards covering conversion formulas, performance considerations, and system optimization for space-constrained installations.
Conception du conduit HVAC: perte de frottement du conduit
Complete guide to HVAC duct friction loss calculations using ASHRAE standards covering friction charts, pressure drop analysis, and system optimization for efficient air distribution design.
Conception du conduit HVAC: classification de la pression des conduits
Complete guide to HVAC duct pressure classification using SMACNA standards covering pressure class selection, construction requirements, and testing protocols for safe and efficient ductwork systems.
Conception du conduit CVC: dimensionnement commercial de conduits de cuisine
Complete guide to commercial kitchen duct sizing using ASHRAE and NFPA standards covering exhaust hood design, grease management, fire safety, and make-up air systems for food service operations.
Conception du conduit CVC: dimensionnement des conduits par des critères de vitesse et de bruit (NC)
Complete guide to HVAC duct sizing using velocity and noise criteria with ASHRAE and CIBSE standards covering acoustic design, velocity limits, and noise control for sensitive applications.
Conception du conduit HVAC: dimensionnement des conduits par méthode de frottement égale
Complete guide to HVAC duct sizing using the equal friction method with SMACNA and ASHRAE standards covering calculation procedures, friction rate selection, and system optimization for effective air distribution design.
Conception du conduit HVAC: recommandations de smacna de dimensionnement des conduits
Complete guide to HVAC duct sizing using SMACNA recommendations covering equal friction, velocity, and static regain methods with design calculations and system optimization for effective air distribution.
Outils Et Ressources Numériques
Fonctions de programmation psychrométrique
ibrary of psychrometric functions to calculate thermodynamic properties of air for Python, C, C#, Fortran, JavaScript and VBA/Excel
Logiciel Carrier Hap
Carrier’s Hourly Analysis Program is two powerful tools in one package – versatile features for designing HVAC systems for commercial buildings AND powerful energy analysis capabilities for comparing energy consumption and operating costs of design alternatives.
Trace 700 Software
TRACE 700 enables building designers to optimize the building, system and equipment designs on the basis of energy utilization and life-cycle cost. The Trane software for TRACE 700 facilitates analysis of the energy and economic effects of virtually any chiller plant configuration by allowing users to manipulate a wide range of variables and create a profile of their specific building.
Télécharger Evap-Cond 5.0: L'outil de simulation de l'échangeur de chaleur ultime pour les ingénieurs HVAC
Que vous conceviez un nouvel échangeur de chaleur, l'optimisation d'un système existant ou que vous recherchiez des réfrigérants alternatifs, EVAP-Cond fournit les capacités d'analyse détaillées nécessaires pour prendre des décisions éclairées. J'encourage tous les ingénieurs et chercheurs CVC à explorer cet outil de simulation puissant et à découvrir de première main comment transformer votre approche en conception de l'échangeur de chaleur.
Téléchargement du manuel de transfert de chaleur
The book is meant for juniors, seniors, and first-year graduate students. And to those who choose to learn the subject on their own, and to practicing engineers who use it as a reference. Whether one studies alone or with a class, learning means posing, then answering, one’s own questions.