Engenharia e Conhecimento

Fundamentos e engenharia

Pump Construction (Part1)

In 1689 the physicist Denis Papin invented the centrifugal pump and today this kind of pump is the most used around the world. The centrifugal pump is built on a simple principle: Liquid is led to the impeller hub and by means of the centrifugal force it is flung towards the periphery of the impellers. The construction is fairly inexpensive, robust and simple and its high speed makes it possible to connect the pump directly to an asynchronous motor.

What Is Corrosion?

Corrosion is usually referred to as the degradation of the metal by chemical or electrochemical reaction with its environment, see figure 1. When considered broadly, corrosion may be looked upon as the tendency of the metal to revert to its natural state similar to the oxide from which it was originally melted. Only precious metals, such as gold and platinum are found in nature in their metallic state. – Types of corrosion – Uniform corrosion – Pitting corrosion – Crevice corrosion – Intergranular corrosion – Selective corrosion – Erosion corrosion – Cavitation corrosion – Stress corrosion cracking (SCC) – Corrosion fatigue – Galvanic corrosion

Expansion Valves Selection

The expansion valve regulates the amount of compressed liquid refrigerant moving into the evaporator. It removes pressure from the liquid refrigerant to allow expansion or change of state from a liquid to a gas in the evaporator. In order to properly select Expansion Valves one should pay attention to the items that we mention in this post.

Water Tube Versus Fire Tube Boilers

Water tube boilers and fire tube boilers are two different types of steam boilers that are commonly used in industrial and commercial applications. Both types of boilers use a system of tubes to generate steam, but they differ in the way that the tubes are arranged and the way that the hot gases from the burner pass through the tubes.

Water Hammer (Part1)

Under unfavorable circumstances, damage due to water hammer may occur in pipelines measuring more than one hundred meters and conveying only several tenths of a liter per second. But even very short, unsupported pipelines in pumping stations can be damaged by resonant vibrations if they are not properly anchored. By contrast, the phenomenon is not very common in building services systems, e.g. in heating and drinking water supply pipelines, which typically are short in length and have a small cross-section.

Capillary Tube Refrigeration

A refrigeration capillary tube is a small, narrow tube that is used in refrigeration systems to control the flow of refrigerant. It is typically made of copper or other highly conductive metal, and is used in conjunction with a compressor, evaporator, and condenser to transfer heat from one location to another. The capillary tube is placed between the evaporator and the compressor in the refrigeration system, and it acts as a metering device to control the flow of refrigerant.

Refrigeration Formulas and Calculations

These formulas are commonly used in the field of refrigeration and air conditioning to calculate various performance parameters of a refrigeration system such as compression work, compression power, coefficient of performance, net refrigeration effect, capacity, compressor displacement, heat of compression, volumetric efficiency, and compression ratio. These formulas are based on the thermodynamics principles and are generally used to evaluate the performance of the refrigeration system and to optimize its design.

The coefficient of velocity (Cv)

Cv, or coefficient of velocity, is a measure of the flow capacity of a valve. It represents the number of gallons per minute (GPM) of water at 60°F that will flow through a valve with a one-inch opening at a pressure drop of one pound per square inch (PSI). Cv can be calculated using various formulas, such as the one based on water at 60F and one that takes into account the specific gravity of the fluid. Cv is a theoretical value and it may vary depending on the actual conditions of the valve. When selecting a valve for a specific application, it is important to consider the Cv in relation to the flow rate and pressure drop requirements of the system, as well as other factors such as ease of maintenance, cost, and safety.

Pipe Insulation Guideline

Pipe insulation is crucial for maintaining energy efficiency, temperature control, condensation control, noise reduction, and safety. ASHRAE provides specific thickness recommendations for different pipe sizes and temperature ranges in its standard 90.1. When selecting pipe insulation based on ASHRAE standards, it’s important to consider the temperature, pipe size, environmental considerations, fire resistance, and energy efficiency.

Refrigerant Piping – part2

In this post, we will be continuing our comprehensive training on how to size refrigerant piping. We will cover all the important aspects of this process, including determining the pipe size, pressure drop, and other factors. We will also discuss topics such as sizing refrigerant lines, equivalent length for refrigerant lines, and how to determine equivalent length. With this training, you will have the knowledge and confidence to size refrigerant piping accurately and correctly in any situation.

Anterior

Padrões e conformidade

Referência padrão do código HVAC - Geral: classificações de edifícios e requisitos de ocupação

Essential guide to HVAC code standards for building classifications and occupancy requirements. Learn how to apply NFPA 101 and ASHRAE 62.1 standards for proper system design and code compliance.

Compreendendo o aquecimento urbano: sistemas eficientes de distribuição de energia para aplicações urbanas sustentáveis ​​– visão geral técnica, instalação, manutenção e padrões para profissionais de HVAC-R

Discover the benefits of district heating in HVAC systems: efficient energy distribution, reduced costs, and integration with renewable sources for sustainable urban development.

Diretrizes ASHRAE sobre expectativa de vida de equipamentos HVAC

Explore ASHRAE life expectancy of HVAC equipment and learn how it guides maintenance and replacement strategies for efficient building management.

Anterior

Ferramentas e recursos digitais

HVAC-R Load Calculator: Your Essential Tool for Accurate System Sizing

Our new web-based calculator combines sophisticated engineering principles with an intuitive interface, making accurate load calculations accessible to everyone from students to seasoned professionals. Unlike basic square-footage estimators, our tool considers the multitude of factors that influence heating and cooling requirements.

Interactive Psychrometric Chart

The aim of this web app is to create an interactive psychrometric chart on which you can project a range of comfort metrics as well as mapping weather data or room air conditions calculated using EnergyPlus. You can add or remove lines for a range of different metrics or highlight them individually to assist with dynamic explanations or presentations.

Financiamento HVAC-R simplificado: apresentando nossa calculadora de equipamentos inteligentes

we’ve developed a comprehensive HVAC-R Equipment Financing Calculator that goes beyond basic loan calculations to include industry-specific considerations like energy savings, equipment efficiency, and available tax incentives

Download Weather Design Conditions (ASHRAE)

Discover ASHRAE Handbook weather stations with our comprehensive search tool. Optimize HVAC and equipment design, sizing, distribution, and installation for residential, commercial, and industrial applications. Enhance your energy-related projects across various sectors, including agriculture, by leveraging accurate climatic data.

Anterior