Resfriamento líquido direto no chip: o futuro do gerenciamento térmico de data centers de alta densidade
Data center power densities have surged to 12-30 kW per rack, making liquid cooling essential. Learn how single-phase and two-phase direct-to-chip systems work, refrigerant selection criteria, and critical design considerations for hoses, tubing, and couplings in modern high-density data centers.
Equilíbrio do fluxo de ar do duto
Balancing air systems (ductwork) may be accomplished in various ways. The most common method to accomplish ductwork balancing is Proportional Method. Each diffuser is adjusted to supply the right percentage of total air volume in the ductwork.
Características da Válvula
Why do we need to be aware of the valve characteristics? Every component in a hydronic system has some level of influence on the control and performance of a hydronic system. Valves are key because they are the controlling devices at the critical areas of heat transfer.
Principais sistemas e equipamentos HVAC
A comprehensive list of all the major HVAC system types and related equipment
Baixar manuais de refrigeração Copeland
This is a five series of publications comprising the Emerson Climate Technologies, Inc. Refrigeration Manual. Although each separate part covers a specific area of refrigeration theory and practice, each successive publication presumes a basic understanding of the material presented in the previous sections.
Sistemas de armazenamento de gelo
Thermal energy storage (TES) involves adding heat (thermal) energy to a storage medium, and then removing it from that medium for use at some other time. This may involve storing thermal energy at high temperatures (heat storage) or at low temperatures (cool storage).
Refrigerant Piping Requirements
This guide focuses on systems that use Refrigerant-22 (R-22). While the general requirements are the same for systems that use other refrigerants, velocities and pressure drops will differ.
Life Cycle Cost Analysis Method
The life-cycle cost analysis method is the most commonly accepted method to assess the economic benefits of energy conservation projects over their lifetime. Typically, the method is used to evaluate at least two alternatives of a given project (for instance, evaluate two alternatives for the installation of a new HVAC system: a VAV system or a heat pump system to condition the building). Only one alternative will be selected for implementation based on the economic analysis.
Padrões e conformidade
HVAC Ventilation Design: Lift/Elevator Pressurization
Complete guide to HVAC lift/elevator pressurization design using BS 5588-4 standards covering pressure control, airflow calculations, and elevator system integration for effective emergency vertical transportation protection.
HVAC Ventilation Design: Staircase Pressurization + Relief Vent Sizing
Complete guide to HVAC staircase pressurization and relief vent sizing design using ASHRAE and BS standards covering pressure control, airflow calculations, and relief system integration for effective emergency egress protection.
HVAC Ventilation Design: Corridor/Lift Lobby/Atrium Make-Up/Pressurization
Complete guide to HVAC corridor, lift lobby, and atrium make-up air and pressurization design using CIBSE and ASHRAE standards covering pressure control, airflow calculations, and fire safety integration for effective emergency protection.
HVAC Ventilation Design: Atrium Smoke Extract
Complete guide to HVAC atrium smoke extraction design using CIBSE and ASHRAE standards covering smoke layer management, extraction calculations, and advanced fire safety integration for large-volume space protection.
Projeto de ventilação HVAC: Extração de fumaça do corredor/elevador
Complete guide to HVAC corridor and lift lobby smoke extraction design using CIBSE fire engineering standards covering smoke removal, pressure management, and life safety system integration for effective emergency ventilation.
Projeto de ventilação HVAC: Sistema CO de estacionamento de automóveis
Complete guide to HVAC car parking CO detection systems using NFPA 720 standards covering carbon monoxide monitoring, alarm systems, ventilation integration, and safety protocols for parking facility protection.
Projeto de ventilação HVAC: taxa de ventilação de reposição de estacionamento por velocidade
Complete guide to HVAC car parking make-up ventilation design using ASHRAE velocity-based methods covering air movement calculations, system integration, and performance optimization for effective parking facility ventilation.
HVAC Ventilation Design: Car Parking Extract Ventilation Rate
Complete guide to HVAC car parking extract ventilation design using CIBSE and BS standards covering CO control, air change rates, and specialized applications for safe and efficient parking facility ventilation systems.
HVAC Ventilation Design: Commercial Kitchen Ventilation Rates (Hood/Canopy, Ceiling Extract/Makeup)
Complete guide to HVAC commercial kitchen ventilation design using ASHRAE, CIBSE, and VA standards covering hood exhaust rates, makeup air requirements, and specialized applications for effective contaminant control and energy efficiency.
Projeto de ventilação HVAC: taxas de ventilação para áreas de fumo/fumantes
Complete guide to HVAC smoking area ventilation design using CIBSE standards covering high-performance ventilation rates, specialized system requirements, and health protection strategies for tobacco use areas.
Ferramentas e recursos digitais
Cooltools Software Download
– Cycle analysis (process design) – comparison of one stage direct expansion cycle and one stage flooded cycle. – System sizing – calculation of component sizes from general criteria. – System simulation – calculating operating conditions in a system with known components. Component calculations – calculation of – components efficiencies and outlet conditions. – Evaluation of operation – evaluation of system efficiency. – Process investigation – e.g. moist air calculations.
Refrigerant Ph Diagram (Part 2)
This article is a continuation of our older article, which was well received by users, so we decided to update the P-H Diagram list and provide you with a more complete list of the world’s commercial refrigerants. You can easily access the high quality refrigerant chart by clicking on the refrigerants listed in the table.
Carrier Plv Pro Download
Carrier’s PLV Pro is a software tool that empowers consulting engineers to make objective and informed decisions about their chiller plant design that go beyond Full Load and IPLV metrics. Results are provided in a professional report or .csv format for further analysis. The tool is for professionals who need a quick and free-of-charge alternative to detailed energy modeling analyses.
Coolselector Download
Coolselector®2 (from Danfoss company) helps to optimize energy consumption and increase efficiency in any HVACR system. Run unbiased calculations based on a set of operating conditions — such as cooling capacity, refrigerant, evaporation, and condensation temperature — and then select the best components for your design.
Air Conditioning Condensate calculator
Air conditioning condensate is the water that is produced as a result of the cooling process in an air conditioning system. When the air conditioning system cools the air in a building, it removes moisture from the air, which condenses on the cool coils of the air conditioning system. This condensation is collected and drained away through a condensate drain pipe. The water that is collected in the condensate drain is typically referred to as air conditioning condensate.
Pipe Pressure Drop Calculations: Essential Equations and Guidelines
Explore the essentials of pipe pressure drop calculations, including key factors affecting pressure drop, commonly used equations, and practical tips for optimizing fluid transportation systems. Learn about software and tools that can assist in streamlining your calculations and enhance the efficiency of your projects. In this blog post, we discussed the importance of understanding pipe pressure drop calculations and their relevance across various industries. We introduced key factors affecting pressure drop, such as pipe diameter, length, flow rate, fluid properties, and pipe roughness. We also examined several equations for calculating pressure drop, including the Darcy-Weisbach, Hazen-Williams, and Colebrook-White equations, discussing their applicability and limitations.
mcquay duct sizer Download
The McQuay Duct Sizer is a specialized software tool designed for HVAC professionals to assist in the accurate and efficient sizing of air ducts. This tool is essential for ensuring optimal performance and energy efficiency in HVAC systems. The McQuay Duct Sizer is available for free download.
Space and Zone Airflow Sizing Calculations in HVAC Systems
Following our previous discussion on the systematic 9-step procedure for designing cooling and heating systems, it’s essential to understand the technical aspects of airflow sizing
Download HVAC-Cx: The Essential Building HVAC Systems Commissioning Tool
As buildings continue to evolve toward higher efficiency and more sophisticated control strategies, tools like HVAC-Cx become increasingly valuable. The software’s ability to systematically detect faults, prioritize issues, and assist with active commissioning represents a significant advancement in building operations technology.