Ingeniería Y Conocimiento

Fundamentos E Ingeniería

Pump Construction (Part1)

In 1689 the physicist Denis Papin invented the centrifugal pump and today this kind of pump is the most used around the world. The centrifugal pump is built on a simple principle: Liquid is led to the impeller hub and by means of the centrifugal force it is flung towards the periphery of the impellers. The construction is fairly inexpensive, robust and simple and its high speed makes it possible to connect the pump directly to an asynchronous motor.

Expansion Valves Selection

The expansion valve regulates the amount of compressed liquid refrigerant moving into the evaporator. It removes pressure from the liquid refrigerant to allow expansion or change of state from a liquid to a gas in the evaporator. In order to properly select Expansion Valves one should pay attention to the items that we mention in this post.

What Is Corrosion?

Corrosion is usually referred to as the degradation of the metal by chemical or electrochemical reaction with its environment, see figure 1. When considered broadly, corrosion may be looked upon as the tendency of the metal to revert to its natural state similar to the oxide from which it was originally melted. Only precious metals, such as gold and platinum are found in nature in their metallic state. – Types of corrosion – Uniform corrosion – Pitting corrosion – Crevice corrosion – Intergranular corrosion – Selective corrosion – Erosion corrosion – Cavitation corrosion – Stress corrosion cracking (SCC) – Corrosion fatigue – Galvanic corrosion

Water Hammer (Part1)

Under unfavorable circumstances, damage due to water hammer may occur in pipelines measuring more than one hundred meters and conveying only several tenths of a liter per second. But even very short, unsupported pipelines in pumping stations can be damaged by resonant vibrations if they are not properly anchored. By contrast, the phenomenon is not very common in building services systems, e.g. in heating and drinking water supply pipelines, which typically are short in length and have a small cross-section.

Water Tube Versus Fire Tube Boilers

Water tube boilers and fire tube boilers are two different types of steam boilers that are commonly used in industrial and commercial applications. Both types of boilers use a system of tubes to generate steam, but they differ in the way that the tubes are arranged and the way that the hot gases from the burner pass through the tubes.

Capillary Tube Refrigeration

A refrigeration capillary tube is a small, narrow tube that is used in refrigeration systems to control the flow of refrigerant. It is typically made of copper or other highly conductive metal, and is used in conjunction with a compressor, evaporator, and condenser to transfer heat from one location to another. The capillary tube is placed between the evaporator and the compressor in the refrigeration system, and it acts as a metering device to control the flow of refrigerant.

Refrigeration Formulas and Calculations

These formulas are commonly used in the field of refrigeration and air conditioning to calculate various performance parameters of a refrigeration system such as compression work, compression power, coefficient of performance, net refrigeration effect, capacity, compressor displacement, heat of compression, volumetric efficiency, and compression ratio. These formulas are based on the thermodynamics principles and are generally used to evaluate the performance of the refrigeration system and to optimize its design.

The coefficient of velocity (Cv)

Cv, or coefficient of velocity, is a measure of the flow capacity of a valve. It represents the number of gallons per minute (GPM) of water at 60°F that will flow through a valve with a one-inch opening at a pressure drop of one pound per square inch (PSI). Cv can be calculated using various formulas, such as the one based on water at 60F and one that takes into account the specific gravity of the fluid. Cv is a theoretical value and it may vary depending on the actual conditions of the valve. When selecting a valve for a specific application, it is important to consider the Cv in relation to the flow rate and pressure drop requirements of the system, as well as other factors such as ease of maintenance, cost, and safety.

Pipe Insulation Guideline

Pipe insulation is crucial for maintaining energy efficiency, temperature control, condensation control, noise reduction, and safety. ASHRAE provides specific thickness recommendations for different pipe sizes and temperature ranges in its standard 90.1. When selecting pipe insulation based on ASHRAE standards, it’s important to consider the temperature, pipe size, environmental considerations, fire resistance, and energy efficiency.

Tubería de refrigerante - parte 2

In this post, we will be continuing our comprehensive training on how to size refrigerant piping. We will cover all the important aspects of this process, including determining the pipe size, pressure drop, and other factors. We will also discuss topics such as sizing refrigerant lines, equivalent length for refrigerant lines, and how to determine equivalent length. With this training, you will have the knowledge and confidence to size refrigerant piping accurately and correctly in any situation.

Anterior

Normas Y Cumplimiento

Estimación de carga de HVAC: ganancia de calor interno de los componentes de infraestructura (tuberías, conductos, tanques, motores de CA)

Complete guide to internal heat gain from HVAC infrastructure components including pipes, ducts, tanks, and motors using Carrier standards for accurate load estimation and system design.

Estimación de carga de HVAC: ganancia de calor interno de equipos y electrodomésticos

Complete guide to internal heat gain from equipment and appliances in HVAC load estimation using ASHRAE, CIBSE, and Carrier standards for accurate system sizing and equipment integration.

Estimación de carga de HVAC: ganancia de calor interno de la iluminación

Complete guide to internal heat gain from lighting systems in HVAC load estimation using ASHRAE, CIBSE, and Carrier standards for accurate system sizing and lighting-HVAC integration.

Estimación de carga de HVAC: ganancia de calor interna de personas y ocupantes

Complete guide to internal heat gain from people and occupants in HVAC load estimation using ASHRAE, CIBSE, Carrier, and NFPA standards for accurate system sizing and design.

HVAC Load Estimation: Glazing U-Values and Shading Coefficient (SC) Values

Complete guide to glazing U-values and shading coefficients for HVAC load estimation using ASHRAE, CIBSE, and Carrier standards for accurate fenestration thermal and solar analysis.

Estimación de carga de HVAC: valores U de construcción para paredes, techos y tabiques

Complete guide to construction U-values for walls, roofs, and partitions in HVAC load estimation using ASHRAE, CIBSE, and Carrier standards for accurate thermal analysis.

HVAC Psychrometric Processes: Charts, Calculations, and Air Treatment Applications

Complete guide to psychrometric processes in HVAC design covering sensible/latent cooling, heating, humidification, dehumidification, and evaporative cooling using ASHRAE and CIBSE standards.

HVAC Cooling and Heating Load Estimation: Outdoor Conditions and Climate Data

Comprehensive guide to outdoor climate data for HVAC load estimation using ASHRAE, CIBSE, and Carrier standards. Essential weather parameters for accurate system sizing and energy analysis.

HVAC System Selection and Design Strategy: Professional Standards and Guidelines

Comprehensive guide to HVAC system selection and design strategy using ASHRAE, SMACNA, and Carrier standards. Learn professional methodologies for optimal system selection and performance optimization.

Ecuaciones de diseño de HVAC: cálculos de aire, ventilador, bomba y sistema hidrónico

Comprehensive guide to essential HVAC design equations covering air, fan, pump, and hydronic system calculations. Reference standards from SMACNA, ASHRAE, and Carrier for professional engineering applications.

Anterior

Herramientas Y Recursos Digitales

Trane Air Conditioning Clinic Books

These clinics are comprehensive and detailed courses used to educate on the fundamentals heating, ventilating, and air conditioning (HVAC). Each clinic includes a student workbook, with corresponding quiz questions/problems.

Carrier Technical Development Programs (Tdp) Books

Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection and application topics. They are targeted at engineers and designers who wish to develop their knowledge in this field to effectively design, specify, sell or apply HVAC equipment in commercial applications.

Manual de diseño del sistema de transporte

Download all 11 chapters of Carrier System Design Manual.

Rhvac – Residential Hvac Loads And Duct Sizes

Rhvac can calculate peak heating and cooling loads (both block and room by room) for residential buildings and some light commercial applications in accordance with ACCA Manual J, D, and S. Rhvac include a complete ACCA Manual D duct sizing capability and a complete Manual S equipment selection.

Colores del contenedor de refrigerante

This guideline is intended for the guidance of the industry, including manufacturers, engineers, installers, contractors and users.

Refrig – Refrigeration Box Loads

Refrig quickly calculates the maximum refrigeration load in btu’s per 24 hour period for all types of refrigeration applications. Refrig has provision for all kinds of loads including: roofs, walls, partitions, floors, products, containers, infiltration, lights, equipment, people, defrost, compressor run-time, and more.

3E Plus Software

NAIMA’s FREE 3E Plus® software program makes it easy to calculate the appropriate insulation thickness necessary for any application. To ensure accuracy, the program has customizable inputs for every aspect of your job—and offers default values if your exact numbers aren’t available.

Refrigerants P-H Diagram

The pressure-enthalpy diagram (log P/h diagram) is a very useful tool for refrigerant technicians, engineers and researchers. Since it’s not always possible to have all of these diagrams together, we decided to give you this complete pack.

Hvacr Equipment Life Expectancy

Below you can see ASHRAE chart of HVAC Equipment Life Expectancy. The chart includes a list of median life expectancy for the following types of equipment:

Anterior