Variable Air Volume (VAV)

The VAV system has a central air-processing unit to produce air at a specified temperature and relative humidity. The conditioned air from the main unit is conveyed in ductwork to ceiling diffusers which incorporate thermostatically controlled actuators. These can change the air volume to suit each room load. In a large room, several of these VAV ceiling units may be controlled by one room thermostat.

Steam Trap Explained Totally

There are many types of steam traps each having its unique characteristics and system benefits. Deciding which type of trap to use is sometimes confusing and, in many cases, more than one type can be used. The following is intended to point out system conditions that may be encountered and the characteristics of each type of trap. Steam Trap – Operation, Advantages, Disadvantages And Primary Applications

Hvac System Components

Refrigeration and HVAC Systems and Equipment components help system designers and operators to select and use equipment that is the best fit for a particular application or controlling scenario.

Pressure Independent Control Valves (PICV)

Pressure Independent Control Valves (PICV) can help reduce energy costs and increase occupant comfort in heating and cooling coil applications in buildings. A PICV is best described as two valves in one: a standard 2-way control valve and a balancing valve.

Humidifier

Depending on the state of the air on entering a spray washer, it can be humidified or dehumidified. Humidification in the presence of moisture is understandable, but dehumidification is less easy to comprehend. It occurs when the spray is at a lower temperature than the air and the dew point of the air.

Data Centers Cooling Systems

In a data center, the HVAC system energy consumption is dependent on three main factors: outdoor conditions (temperature and humidity), the use of economization strategies, and the primary type of cooling consider the following:

Chilled Beams And Ceilings

Chilled beams and chilled ceilings require a relatively modest cooling water temperature (14–17°C), which can be obtained using natural cold water storage or free cooling from outside air over periods of the year depending on climate.

तीन-तरफ़ा नियंत्रण वाल्व

Three-way valves provide for variable flow through the coil while maintaining somewhat constant flow in the system. While three-way valves are most commonly used where constant fluid flow is desired, in reality they will not result in constant flow no matter which plug style is selected.

दोतरफा नियंत्रण वाल्व

The control valve is possibly the most important component of a fluid distribution system because it regulates the flow of fluid to the process under control. In HVAC systems, control valves are primarily used to control the flow of chilled water, hot water, and condenser water, the subject of this section.

Previous

नियंत्रण और स्वचालन

डायरेक्ट-टू-चिप लिक्विड कूलिंग: उच्च-घनत्व डेटा सेंटर थर्मल प्रबंधन का भविष्य

डेटा सेंटर पावर घनत्व प्रति रैक 12-30 किलोवाट तक बढ़ गया है, जिससे तरल शीतलन आवश्यक हो गया है। जानें कि एकल-चरण और दो-चरण डायरेक्ट-टू-चिप सिस्टम कैसे काम करते हैं, रेफ्रिजरेंट चयन मानदंड, और आधुनिक उच्च-घनत्व डेटा केंद्रों में होसेस, ट्यूबिंग और कपलिंग के लिए महत्वपूर्ण डिजाइन विचार।

एचवीएसी नियंत्रण आरेख

इस ब्लॉग पोस्ट में, हम कुछ सबसे सामान्य एचवीएसी नियंत्रण आरेख पेश करेंगे। हम प्रत्येक आरेख का संक्षिप्त विवरण भी प्रदान करेंगे और उसके घटक एक साथ कैसे काम करते हैं। एचवीएसी नियंत्रण आरेख एचवीएसी सिस्टम को डिजाइन करने, स्थापित करने और बनाए रखने के लिए आवश्यक उपकरण हैं। वे सिस्टम के घटकों का एक दृश्य प्रतिनिधित्व प्रदान करते हैं, वे कैसे आपस में जुड़े हुए हैं, और उन्हें कैसे नियंत्रित किया जाता है। इस जानकारी का उपयोग समस्याओं का निवारण करने, प्रदर्शन को अनुकूलित करने और सिस्टम अपग्रेड के बारे में सूचित निर्णय लेने के लिए किया जा सकता है।