Systeme und Ausrüstung

Ausrüstung & Systeme

Variable Air Volume (VAV)

The VAV system has a central air-processing unit to produce air at a specified temperature and relative humidity. The conditioned air from the main unit is conveyed in ductwork to ceiling diffusers which incorporate thermostatically controlled actuators. These can change the air volume to suit each room load. In a large room, several of these VAV ceiling units may be controlled by one room thermostat.

Steam Trap Explained Totally

There are many types of steam traps each having its unique characteristics and system benefits. Deciding which type of trap to use is sometimes confusing and, in many cases, more than one type can be used. The following is intended to point out system conditions that may be encountered and the characteristics of each type of trap. Steam Trap – Operation, Advantages, Disadvantages And Primary Applications

Hvac System Components

Refrigeration and HVAC Systems and Equipment components help system designers and operators to select and use equipment that is the best fit for a particular application or controlling scenario.

Pressure Independent Control Valves (PICV)

Pressure Independent Control Valves (PICV) can help reduce energy costs and increase occupant comfort in heating and cooling coil applications in buildings. A PICV is best described as two valves in one: a standard 2-way control valve and a balancing valve.

Humidifier

Depending on the state of the air on entering a spray washer, it can be humidified or dehumidified. Humidification in the presence of moisture is understandable, but dehumidification is less easy to comprehend. It occurs when the spray is at a lower temperature than the air and the dew point of the air.

Data Centers Cooling Systems

In a data center, the HVAC system energy consumption is dependent on three main factors: outdoor conditions (temperature and humidity), the use of economization strategies, and the primary type of cooling consider the following:

Chilled Beams And Ceilings

Chilled beams and chilled ceilings require a relatively modest cooling water temperature (14–17°C), which can be obtained using natural cold water storage or free cooling from outside air over periods of the year depending on climate.

Three-Way Control Valves

Three-way valves provide for variable flow through the coil while maintaining somewhat constant flow in the system. While three-way valves are most commonly used where constant fluid flow is desired, in reality they will not result in constant flow no matter which plug style is selected.

Two-Way Control Valves

The control valve is possibly the most important component of a fluid distribution system because it regulates the flow of fluid to the process under control. In HVAC systems, control valves are primarily used to control the flow of chilled water, hot water, and condenser water, the subject of this section.

Previous

Steuerelemente und Automatisierung

Direct-to-Chip-Flüssigkeitskühlung: Die Zukunft des Wärmemanagements in Rechenzentren mit hoher Dichte

Die Leistungsdichte von Rechenzentren ist auf 12–30 kW pro Rack gestiegen, was eine Flüssigkeitskühlung unerlässlich macht. Erfahren Sie, wie einphasige und zweiphasige Direct-to-Chip-Systeme funktionieren, welche Kältemittelauswahlkriterien es gibt und welche wichtigen Designüberlegungen für Schläuche, Rohre und Kupplungen in modernen Rechenzentren mit hoher Dichte zu beachten sind.

HVAC-Steuerungsdiagramme

In diesem Blogbeitrag stellen wir einige der gängigsten HVAC-Steuerungsdiagramme vor. Außerdem geben wir eine kurze Erläuterung zu jedem Diagramm und wie seine Komponenten zusammenarbeiten. HVAC-Steuerungsdiagramme sind wesentliche Werkzeuge für die Planung, Installation und Wartung von HVAC-Systemen. Sie bieten eine visuelle Darstellung der Systemkomponenten, wie sie miteinander verbunden sind und wie sie gesteuert werden. Mithilfe dieser Informationen können Probleme behoben, die Leistung optimiert und fundierte Entscheidungen über Systemaktualisierungen getroffen werden.