الأساسيات والهندسة
التخزين الحراري (HVAC)
Thermal energy may be stored in three main ways: – Sensible Storage – Latent Storage – Thermo-Chemical Storage. In addition, the two common thermal storage strategies employed are: – Load Levelling Strategy – Load Shifting Strategy
تحجيم خزان المياه الهوائية
Hydropneumatic tanks are primarily used in a domestic water system for draw down purposes when the pressure booster system is off on no-flow shutdown (NFSD). The NFSD circuitry turns the lead pump off when there is no demand on the system. While the system is off in this condition, the hydropneumatic tank will satisfy small demands on the system. Without the tank, the booster would restart upon the slightest call for flow such as a single toilet being flushed or even a minute leak in the piping system. Hydropneumatic tank sizing is dependent on two factors: – Length of time you wish the pumps to remain off in a no-flow situation. – The tank location in relation to the pressure booster.
Pump Sizing Core Concepts
Pump sizing involves matching the flow and pressure rating of a pump with the flowrate and pressure required for the process. The mass flowrate of the system is established on the process flow diagram by the mass balance. Achieving this mass flowrate requires a pump that can generate a pressure high enough to overcome the hydraulic resistance of the system of pipes, valves, and so on that the liquid must travel through. This hydraulic resistance is known as the system head.
Hvac Equations (U.S./Metric)
The heating, ventilation, and air conditioning (HVAC) equations. In both U.S. and Metric units.
Expansion Tanks
How does Boyle’s law relate to sizing expansion tanks in domestic hot water systems? what size expansion tank is required?
Expansion Tank Sizing Formulas
Expansion tanks are a necessary part of all closed hydronic systems to control both minimum and maximum pressure throughout the system. A comprehensive review of tank types and sizing procedure for expansion tanks.
الضخ الابتدائي الثانوي
– What is Primary-Secondary Pumping? – PRIMARY-SECONDARY BASICS. – PRIMARY-SECONDARY RULES, DEFINITIONS. WHEN TWO PIPING CIRCUITS ARE INTER-CONNECTED, FLOW IN ONE WILL CAUSE FLOW IN THE OTHER, T0 A DEGREE DEPENDING UPON THE PRESSURE DROP IN THE PIPING COMMON T0 BOTH.
4 أنبوب و 2 أنابيب تسخين وتبريد النباتات
يحتوي مصنع التدفئة والتبريد 4 أنابيب على كلاً من معدات التدفئة والتبريد المركزية وقادرة على توصيل مياه التدفئة والمياه المبردة إلى المبنى في وقت واحد من خلال أربعة أنابيب (إمدادات مياه التدفئة ، عودة مياه التدفئة ، إمدادات المياه المبردة ، وعودة واحدة للمياه). معدات التدفئة والتبريد داخل المبنى المتصل بنظام 4 أنبوب سيكون لها أربعة اتصالات أنابيب ، ما لم يوفر الجهاز التدفئة فقط أو التبريد فقط. في هذه الحالة ، سيكون للمعدات توصيلان للأنابيب فقط.
أنظمة حجم الهواء المستمر (CAV)
HVAC air systems can be either centralized or decentralized. Centralized air systems receive their cooling and heating energy from a remote central plant. Decentralized HVAC air systems contain the central heating and cooling plant equipment within the air system itself. HVAC air systems can also be constant air volume (CAV) or variable air volume (VAV). CAV systems deliver constant supply airflow at a variable temperature. VAV systems deliver variable supply airflow at a constant temperature. CAV and VAV air systems can be further subdivided into systems that condition a single temperature zone and systems that condition multiple temperature zones.
بناء المضخة (الجزء الأول)
In 1689 the physicist Denis Papin invented the centrifugal pump and today this kind of pump is the most used around the world. The centrifugal pump is built on a simple principle: Liquid is led to the impeller hub and by means of the centrifugal force it is flung towards the periphery of the impellers. The construction is fairly inexpensive, robust and simple and its high speed makes it possible to connect the pump directly to an asynchronous motor.
المعايير والامتثال
تصميم قناة HVAC: خسارة الاحتكاك في تجهيزات القناة
Complete guide to HVAC duct fittings friction loss using Carrier standards covering loss coefficients, pressure drop calculations, and system optimization for efficient air distribution design.
تصميم قناة HVAC: مخمدات ، مخففات ، وفقدان الاحتكاك لفائف
Complete guide to HVAC dampers, attenuators, and coils friction loss using SMACNA standards covering pressure drop calculations, component selection, and system optimization for efficient air distribution design.
تصميم قناة HVAC: قناة جولة إلى ما يعادلها مستطيلة
Complete guide to HVAC round-to-rectangular duct equivalency using ASHRAE standards covering conversion formulas, performance considerations, and system optimization for space-constrained installations.
تصميم قناة HVAC: فقدان احتكاك القناة
Complete guide to HVAC duct friction loss calculations using ASHRAE standards covering friction charts, pressure drop analysis, and system optimization for efficient air distribution design.
تصميم قناة HVAC: تصنيف ضغط القناة
Complete guide to HVAC duct pressure classification using SMACNA standards covering pressure class selection, construction requirements, and testing protocols for safe and efficient ductwork systems.
تصميم قناة HVAC: تغيير حجم قناة المطبخ التجاري
Complete guide to commercial kitchen duct sizing using ASHRAE and NFPA standards covering exhaust hood design, grease management, fire safety, and make-up air systems for food service operations.
تصميم قناة HVAC: تحجيم القناة حسب معايير السرعة والضوضاء (NC)
Complete guide to HVAC duct sizing using velocity and noise criteria with ASHRAE and CIBSE standards covering acoustic design, velocity limits, and noise control for sensitive applications.
تصميم قناة HVAC: تحجيم القناة بواسطة طريقة الاحتكاك المتساوي
Complete guide to HVAC duct sizing using the equal friction method with SMACNA and ASHRAE standards covering calculation procedures, friction rate selection, and system optimization for effective air distribution design.
HVAC Duct Design: Duct Sizing SMACNA Recommendations
Complete guide to HVAC duct sizing using SMACNA recommendations covering equal friction, velocity, and static regain methods with design calculations and system optimization for effective air distribution.
الأدوات والموارد الرقمية
Rates Of Thermal Expansion For Common Pipe Materials
Effortlessly calculate rates of thermal expansion for common pipe materials with our interactive calculator. Get accurate data, design insights, and actionable tables for metals and plastics—essential for HVAC engineers, designers, and consultants focused on system reliability and energy efficiency.
حاسبة HVAC Equipman
لقد أنشأنا آلة حاسبة متوقعة معدات HVAC احترافية. يوفر التطبيق حسابات شاملة لتحديد العمر الإنتاجي المتبقي لأنواع معدات HVAC المختلفة.
حلول برامج BIM لتطبيقات HVAC الحديثة
مع استمرار تطور صناعة HVAC في عام 2025 ، أصبحت نمذجة المعلومات (BIM) أداة لا غنى عنها للمهنيين الذين يسعون إلى تحسين عمليات التصميم والتركيب والصيانة. بالنسبة لمهندسي HVAC والمقاولين والفنيين ، فإن اختيار برنامج BIM الصحيح يمكن أن يؤثر بشكل كبير على كفاءة المشروع والنتائج. دعنا نستكشف حلول BIM الأكثر فعالية لتطبيقات HVAC.
McQuay Postwares Download
McQuay (As part of Daikin Industries) is one of the largest air conditioning, heating, ventilating and refrigeration companies in the HVAC/R industry. Therefore, we decided to make some softwares that this company has introduced to the industry based on their experience and knowledge available for download.
برامج Bell & Gossett Selection
#Xylem Bell & Gosset #Selection ، #Sization & #CAD Tools و #SoftWares
ملفات Daikin Revit
مكتبة الموارد التطبيقية Daikin-ملفات Revit Systems Systems معالجات الهواء-الهواء المبرد الهواء في الهواء الطلق مبرد المبردات المبردات المبرد
Cooltools تنزيل البرامج
- تحليل الدورة (تصميم العملية) - مقارنة دورة التوسع المباشر في مرحلة واحدة ودورة واحدة غمرتها المياه. - تحجيم النظام - حساب أحجام المكونات من المعايير العامة. - محاكاة النظام - حساب ظروف التشغيل في نظام مع مكونات معروفة. حسابات المكونات - حساب - كفاءة المكونات وظروف المخرج. - تقييم التشغيل - تقييم كفاءة النظام. - التحقيق في العملية - على سبيل المثال حسابات الهواء الرطبة.