Fundamentals & Engineering
Design Procedures for Heating-Only Systems: An 8-Step Methodology
Designing effective heating-only HVAC systems requires a methodical approach that ensures adequate capacity while avoiding oversizing. The following 8-step procedure provides a comprehensive framework for designing these systems, focusing on peak heating loads to determine appropriate equipment sizing.
Space and Zone Airflow Sizing Calculations in HVAC Systems
Following our previous discussion on the systematic 9-step procedure for designing cooling and heating systems, it’s essential to understand the technical aspects of airflow sizing
Design Procedures for Cooling-Only Systems: Detailed Airflow Calculation Methodology
this technical supplement provides detailed insights into the critical airflow calculation methods essential for Step 3: Calculate Required Zone and Space Supply Airflow Rates. Understanding these calculation approaches enables engineers to select the most appropriate sizing method for specific project requirements.
Design Procedures for Heating-Only Systems: Airflow Calculation Methods and Technical Considerations
Proper airflow calculations are essential for system performance, ensuring thermal comfort while optimizing energy efficiency. Understanding the mathematical foundation behind these calculations enables engineers to make informed decisions when selecting the most appropriate sizing method for specific project requirements.
Refrigeration Expansion Valve Sizing and Selection Process
The proper selection and sizing of refrigeration expansion valves is a systematic process requiring careful consideration of multiple parameters. Selecting the right expansion valve involves understanding system requirements, calculating correct capacities, and accounting for operating conditions such as subcooling and pressure drop.
Refrigeration Evaporator Sizing and Selection
Evaporator sizing and selection represent critical elements in refrigeration system design. The process requires a methodical approach that considers not only the cooling load but also system integration, refrigerant properties, application requirements, and energy efficiency goals.
Lighting Rules Of Thumb (HVAC)
Using lighting rules of thumb for final design of HVAC and lighting.
Infiltration Rules Of Thumb
The infiltration rate is the volumetric flow rate of outside air into a building, typically in cubic feet per minute (CFM) or liters per second (LPS). The air exchange rate, (I), is the number of interior volume air changes that occur per hour, and has units of 1/h.
The Geometry Behind Solar Energy Calculations
Solar Geometric Angles are all critical to the calculation of solar energy on any given surface at some orientation. To calculate the energy balance across any time scale with respect to the incident solar radiation, you must know the geometric relationships that define the spherical realities of planetary motion relative to the sun for specific tilted surfaces on the planet.
Standards & Compliance
HVAC Ventilation Design: Exhaust Air Ventilation By Rate and ACH
Complete guide to HVAC exhaust air ventilation design using ASHRAE, CIBSE, and Carrier standards covering rate calculations, ACH requirements, and specialized applications for effective contaminant removal and energy efficiency.
HVAC Ventilation Design: Outdoor Air Ventilation By Rate and ACH
Complete guide to HVAC outdoor air ventilation design using ASHRAE, CIBSE, and Carrier standards covering rate calculations, ACH requirements, and building-specific applications for optimal indoor air quality.
HVAC Ventilation Design: Indoor Air Quality and Air Contaminants
Complete guide to HVAC indoor air quality and air contaminant management using ASHRAE, CIBSE standards covering contaminant identification, control strategies, and advanced treatment technologies for healthy indoor environments.
HVAC Ventilation Design: Air Intake Minimum Separation Distance
Complete guide to HVAC air intake minimum separation distances using ASHRAE 62.1 standards covering contamination source requirements, measurement methods, and compliance strategies for optimal outdoor air quality protection.
HVAC Ventilation Design: Air Classifications
Complete guide to HVAC air classifications using ASHRAE 62.1 and CIBSE standards covering air quality categories, contamination levels, filtration requirements, and ventilation strategies for optimal indoor environmental control.
HVAC Ventilation Design: General Schematic and Equations
Complete guide to HVAC ventilation design using ASHRAE 62.1 standards covering calculation procedures, system schematics, and modern ventilation strategies for optimal indoor air quality and energy efficiency.
HVAC Load Estimation: Fouling Factor
Complete guide to fouling factors in HVAC load estimation using Carrier water conditioning standards for accurate heat transfer equipment sizing and comprehensive water quality management strategies.
HVAC Load Estimation: Diversity Factor
Complete guide to diversity factors in HVAC load estimation using CIBSE and Carrier standards for accurate system sizing that reflects realistic building operation patterns and prevents equipment oversizing.
HVAC Load Estimation: Indoor Design Conditions and System Requirements by Building Type
Complete guide to indoor design conditions for HVAC load estimation covering temperature, humidity, air quality, and specialized requirements for residential, commercial, industrial, healthcare, and specialty building applications using ASHRAE, CIBSE, and Carrier standards.
HVAC Load Estimation: Infiltration Heat Gain and Loss
Complete guide to infiltration in HVAC load estimation using ASHRAE, CIBSE, and Carrier standards for accurate assessment of uncontrolled air exchange and its impact on heating and cooling loads.
Digital Tools & Resources
Belimo SelectPro – Free Download
Download SelectPro desktop app free. Size and select valves, actuators, and sensors with export builder, quote generator, and centralized reference documents. For HVAC engineers and contractors.
Rates Of Thermal Expansion For Common Pipe Materials
Effortlessly calculate rates of thermal expansion for common pipe materials with our interactive calculator. Get accurate data, design insights, and actionable tables for metals and plastics—essential for HVAC engineers, designers, and consultants focused on system reliability and energy efficiency.
HVAC Equipment Life Expectancy Calculator
We’ve created a professional HVAC equipment life expectancy calculator. The application provides comprehensive calculations for determining the remaining useful life of various HVAC equipment types.
BIM Software Solutions for Modern HVAC Applications
As the HVAC industry continues to evolve in 2025, Building Information Modeling (BIM) has become an indispensable tool for professionals seeking to optimize design, installation, and maintenance processes. For HVAC engineers, contractors, and technicians, selecting the right BIM software can significantly impact project efficiency and outcomes. Let’s explore the most effective BIM solutions for HVAC applications.
Mcquay Softwares Download
McQuay (As part of Daikin Industries) is one of the largest air conditioning, heating, ventilating and refrigeration companies in the HVAC/R industry. Therefore, we decided to make some softwares that this company has introduced to the industry based on their experience and knowledge available for download.
Bell & Gossett Selection Softwares
#Xylem Bell & Gosset #Selection, #Sizing & #CAD Tools and #Softwares
Daikin Revit Files
DAIKIN APPLIED RESOURCE LIBRARY – REVIT FILES Rooftop Systems Air Handlers – Outdoor Air Cooled Chillers Water Cooled Chillers Fan Coils Self-Contained Water Source Heat Pump Unit Ventilators