अभियांत्रिकी और ज्ञान

फंडामेंटल एंड इंजीनियरिंग

Space and Zone Airflow Sizing Calculations in HVAC Systems

Following our previous discussion on the systematic 9-step procedure for designing cooling and heating systems, it’s essential to understand the technical aspects of airflow sizing

Design Procedures for Cooling-Only Systems: Detailed Airflow Calculation Methodology

this technical supplement provides detailed insights into the critical airflow calculation methods essential for Step 3: Calculate Required Zone and Space Supply Airflow Rates. Understanding these calculation approaches enables engineers to select the most appropriate sizing method for specific project requirements.

Design Procedures for Heating-Only Systems: Airflow Calculation Methods and Technical Considerations

Proper airflow calculations are essential for system performance, ensuring thermal comfort while optimizing energy efficiency. Understanding the mathematical foundation behind these calculations enables engineers to make informed decisions when selecting the most appropriate sizing method for specific project requirements.

प्रशीतन विस्तार वाल्व आकार और चयन प्रक्रिया

The proper selection and sizing of refrigeration expansion valves is a systematic process requiring careful consideration of multiple parameters. Selecting the right expansion valve involves understanding system requirements, calculating correct capacities, and accounting for operating conditions such as subcooling and pressure drop.

प्रशीतन बाष्पीकरणकर्ता आकार और चयन

बाष्पीकरणकर्ता आकार और चयन प्रशीतन प्रणाली डिजाइन में महत्वपूर्ण तत्वों का प्रतिनिधित्व करते हैं। प्रक्रिया के लिए एक व्यवस्थित दृष्टिकोण की आवश्यकता होती है जो न केवल शीतलन लोड, बल्कि सिस्टम एकीकरण, सर्द गुण, अनुप्रयोग आवश्यकताओं और ऊर्जा दक्षता लक्ष्यों पर भी विचार करता है।

Lighting Rules Of Thumb (HVAC)

Using lighting rules of thumb for final design of HVAC and lighting.

अंगूठे के घुसपैठ नियम

The infiltration rate is the volumetric flow rate of outside air into a building, typically in cubic feet per minute (CFM) or liters per second (LPS). The air exchange rate, (I), is the number of interior volume air changes that occur per hour, and has units of 1/h.

कूलिंग लोड गणना प्रक्रिया

एचवीएसी डिज़ाइन के लिए कूलिंग लोड गणना प्रक्रिया। भवन की विशेषताएं प्राप्त करने से लेकर बाहरी डिज़ाइन, मौसम की स्थिति और प्रत्येक स्थान में बनाए रखने के लिए इनडोर डिज़ाइन तापमान तक।

The Geometry Behind Solar Energy Calculations

Solar Geometric Angles are all critical to the calculation of solar energy on any given surface at some orientation. To calculate the energy balance across any time scale with respect to the incident solar radiation, you must know the geometric relationships that define the spherical realities of planetary motion relative to the sun for specific tilted surfaces on the planet.

एचवीएसी लोड गणना

मूलभूत भवन डिजाइन निर्णयों और एक परिचालन भवन के बीच एक मजबूत पुल प्रदान करने के लिए हीटिंग और कूलिंग भार की सटीक गणना आवश्यक है। यदि भार को काफी हद तक कम आंका गया है, तो रहने वालों और उपयोगकर्ताओं को गर्मी या ठंड लगने की संभावना होगी। यदि भार को काफी हद तक बढ़ा दिया गया है, तो उपकरण बड़े आकार के हो जाएंगे (आमतौर पर पैसे की बर्बादी, दक्षता कम करना, ऊर्जा की खपत में वृद्धि और अक्सर आराम को खतरे में डालना)।

Previous

मानकों का अनुपालन

HVAC Duct Design: Duct Fittings Friction Loss

Complete guide to HVAC duct fittings friction loss using Carrier standards covering loss coefficients, pressure drop calculations, and system optimization for efficient air distribution design.

HVAC Duct Design: Dampers, Attenuators, and Coils Friction Loss

Complete guide to HVAC dampers, attenuators, and coils friction loss using SMACNA standards covering pressure drop calculations, component selection, and system optimization for efficient air distribution design.

HVAC Duct Design: Duct Round to Rectangular Equivalent

Complete guide to HVAC round-to-rectangular duct equivalency using ASHRAE standards covering conversion formulas, performance considerations, and system optimization for space-constrained installations.

HVAC Duct Design: Duct Friction Loss

Complete guide to HVAC duct friction loss calculations using ASHRAE standards covering friction charts, pressure drop analysis, and system optimization for efficient air distribution design.

HVAC Duct Design: Duct Pressure Classification

Complete guide to HVAC duct pressure classification using SMACNA standards covering pressure class selection, construction requirements, and testing protocols for safe and efficient ductwork systems.

HVAC Duct Design – Sizing Contaminant-Extraction Ducts (Smoke | Grease | Gases | Dry & Moist Dust)

ASHRAE’s Pocket Guide lists minimum conveying velocities that keep contaminants airborne while they travel through exhaust ductwork. Table 2.9 (2013 edition, Ch. 02, pp. 60

HVAC Duct Design: Commercial Kitchen Duct Sizing

Complete guide to commercial kitchen duct sizing using ASHRAE and NFPA standards covering exhaust hood design, grease management, fire safety, and make-up air systems for food service operations.

HVAC Duct Design: Duct Sizing by Velocity & Noise Criteria (NC)

Complete guide to HVAC duct sizing using velocity and noise criteria with ASHRAE and CIBSE standards covering acoustic design, velocity limits, and noise control for sensitive applications.

HVAC Duct Design: Duct Sizing by Equal Friction Method

Complete guide to HVAC duct sizing using the equal friction method with SMACNA and ASHRAE standards covering calculation procedures, friction rate selection, and system optimization for effective air distribution design.

HVAC Duct Design: Duct Sizing SMACNA Recommendations

Complete guide to HVAC duct sizing using SMACNA recommendations covering equal friction, velocity, and static regain methods with design calculations and system optimization for effective air distribution.


अंकीय उपकरण और संसाधन

Rates Of Thermal Expansion For Common Pipe Materials

Effortlessly calculate rates of thermal expansion for common pipe materials with our interactive calculator. Get accurate data, design insights, and actionable tables for metals and plastics—essential for HVAC engineers, designers, and consultants focused on system reliability and energy efficiency.

एचवीएसी उपकरण जीवन प्रत्याशा कैलकुलेटर

हमने एक पेशेवर एचवीएसी उपकरण जीवन प्रत्याशा कैलकुलेटर बनाया है। एप्लिकेशन विभिन्न एचवीएसी उपकरण प्रकारों के शेष उपयोगी जीवन का निर्धारण करने के लिए व्यापक गणना प्रदान करता है।

आधुनिक एचवीएसी अनुप्रयोगों के लिए बीआईएम सॉफ्टवेयर समाधान

जैसा कि एचवीएसी उद्योग 2025 में विकसित होना जारी है, निर्माण सूचना मॉडलिंग (बीआईएम) डिजाइन, स्थापना और रखरखाव प्रक्रियाओं को अनुकूलित करने के लिए पेशेवरों के लिए एक अपरिहार्य उपकरण बन गया है। एचवीएसी इंजीनियरों, ठेकेदारों और तकनीशियनों के लिए, सही बीआईएम सॉफ्टवेयर का चयन करना परियोजना दक्षता और परिणामों को महत्वपूर्ण रूप से प्रभावित कर सकता है। चलो HVAC अनुप्रयोगों के लिए सबसे प्रभावी BIM समाधानों का पता लगाएं।

मैक्वे सॉफ्टवेयर्स डाउनलोड करें

McQuay (Daikin Industries के हिस्से के रूप में) HVAC/R उद्योग में सबसे बड़ी एयर कंडीशनिंग, हीटिंग, हवादार और प्रशीतन कंपनियों में से एक है। इसलिए, हमने कुछ सॉफ्टवेयर्स बनाने का फैसला किया कि इस कंपनी ने उद्योग को उनके अनुभव और ज्ञान के आधार पर डाउनलोड के लिए उपलब्ध कराया है।

बेल और गॉसेट चयन सॉफ्टवेयर

#Xylem बेल और गॉसेट #सेलेक्शन, #sizing & #cad टूल्स और #softwares

एचवीएसी कैरियर के अवसर

एचवीएसी / आर (हीटिंग, वेंटिलेटिंग, और एयर कंडीशनिंग / रेफ्रिजरेशन) उद्योग तेजी से बदल रहा है, जिससे प्रौद्योगिकी में प्रगति के कारण ऊर्जा क्षमता में वृद्धि की आवश्यकता होती है। तदनुसार, एचवीएसी क्षेत्रों में रोजगार की मांग करने वाले व्यक्ति के लिए खुले कैरियर के अवसर लगभग चार श्रेणियों में विभाजित किए जा सकते हैं, प्रत्येक एक अलग प्रकार या शिक्षा और/या प्रशिक्षण की डिग्री पर निर्भर है।

पाइप अनुसूचियां टेबल्स

पाइप शेड्यूल (SCH) एक मानक है जो एक पाइप की नाममात्र दीवार की मोटाई को मापता है। पाइप अनुसूची संख्या गैर-आयामी है और नाममात्र पाइप आकार, आंतरिक पाइप काम करने के दबाव और पाइप की दीवार के लिए उपयोग की जाने वाली सामग्री पर निर्भर करती है।

पाइपिंग उपकरण (एक्सेल फ़ाइलें)

द्रव, थर्मल और पाइपिंग इंजीनियरिंग में गणना की एक व्यापक श्रेणी के लिए 165 से अधिक स्प्रेडशीट (एक्सेल एक्सएलएस फाइलें)।

Daikin Revit फ़ाइलें

Daikin एप्लाइड रिसोर्स लाइब्रेरी-Revit Files Rooftop Systems Air Handlers-आउटडोर एयर कूल्ड चिलर्स वाटर कूल्ड चिलर्स फैन कॉइल स्व-निहित वाटर सोर्स हीट पंप यूनिट वेंटिलेटर्स

कूलटूल्स सॉफ्टवेयर डाउनलोड

- चक्र विश्लेषण (प्रक्रिया डिजाइन) - एक चरण प्रत्यक्ष विस्तार चक्र और एक चरण में बाढ़ चक्र की तुलना। - सिस्टम साइज़िंग - सामान्य मानदंडों से घटक आकारों की गणना। - सिस्टम सिमुलेशन - ज्ञात घटकों के साथ एक प्रणाली में परिचालन स्थितियों की गणना करना। घटक गणना - घटकों की गणना - प्रभावशीलता और आउटलेट की स्थिति। - ऑपरेशन का मूल्यांकन - सिस्टम दक्षता का मूल्यांकन। - प्रक्रिया जांच - जैसे नम वायु गणना।